ZAON PCAS XRX installation
3) Connection through DOCKING STATION – Serial interface
WHAT IS NEEDED:
PCAS XRX interface cable
Optional (product code CBDJMG0400)
The cable must be cut to uncover the 4
free wires to connect to the Docking
Station.
Instructions:
1.Connect the white RXA of the PCAS
XRX interface cable to the Docking
Station clamp board, PIN labeled as
RXA.
2. Connect the yellow TXA of the
PCAS XRX interface cable to the
Docking Station clamp board, PIN
labeled as TXA.
3. Connect the black GND of the
PCAS XRX interface cable to the
Docking Station clamp board, PIN
labeled as GND.
4. Plug the serial connector of the
PCAS XRX interface cable to the Zaon
PCAS XRX.
PCAS XRX interface cable
Optional CBDJMG0400
Standard version
TXA
GND
Serial
interface
“A
RXA